Pipe Loop Drawings

Installer-ready loop layouts with centres, lengths and circuit numbering resolved on the drawing.

Pipe Loop Drawings — representative deliverable
Overview

Pipe Loop Drawings

The loop drawing is what the installer holds while kneeling on a screed base. If it does not show pipe centres, circuit numbering, loop length and where the pipe crosses an expansion joint, those decisions get made on site — and the balancing schedule that was calculated for a different layout stops meaning anything.

We draw loops properly. Centres vary within a room where the calculation requires it, typically tightening in the perimeter zone. Loop lengths are kept within the pressure drop limit for the pipe diameter and reported per circuit. Every circuit is numbered to match its manifold port, and pipe crossings at doorways and movement joints are detailed rather than left to improvisation.

Where the room shape makes a clean serpentine impossible — and in real buildings it often does — the layout is resolved on the drawing rather than described in a note.

What you receive

Every item below is issued in your own template, with your layer conventions, title block and revision scheme.

  • Loop layout per floor with pipe routing drawn at scale
  • Pipe centres annotated per room, including perimeter zone variation
  • Loop length and circuit number for every circuit
  • Circuit-to-manifold port cross-reference
  • Pipe crossing details at doorways, thresholds and movement joints
  • Expansion and edge joint positions with pipe sleeving requirements
  • Fixing method and spacing notes for the specified system
  • Total pipe quantity by diameter for procurement
  • Screed depth and cover confirmation per area

Production detail

Key production parameters for Pipe Loop Drawings
Typical turnaround24 hours per dwelling floor
Pipe centres100 / 150 / 200 / 300 mm, varied by zone as calculated
Loop length limitsBy diameter and pressure drop; typically 80–120 m for 16 mm
Layout patternsSerpentine, counterflow spiral, perimeter-weighted
Output formatsDWG, PDF at plot scale, XLSX circuit schedule
RevisionsTwo rounds included

Software and formats

We work in your toolchain. If something you use is not listed, ask — the list below is only what we use most.

LinearAutoCADMagiCADRevit

Frequently asked

Whichever the situation calls for. Counterflow spiral gives a more even surface temperature and suits large open areas; serpentine is easier to install and better for narrow or awkward rooms and for perimeter weighting. We choose per room and note the reasoning where it is not obvious.

By splitting the room across multiple circuits with the division drawn on the layout, and by adjusting centres so each circuit's pressure drop stays inside the limit for the pipe diameter. Loop lengths are reported per circuit so the balancing schedule matches what gets installed.

Yes, with the sleeving detail and the crossing position dimensioned. Uncontrolled crossings at movement joints are one of the more common causes of later failure, so we do not leave them to the drawing note.

Yes. Send the heat loss schedule and required outputs and we will draw to them. We will sanity-check the numbers as we go and raise anything that looks inconsistent, but the calculation basis remains the original designer's.