Heat Loss Calculations

Room-by-room BS EN 12831 calculations with the fabric and ventilation basis shown in full.

Heat Loss Calculations — representative deliverable
Overview

Heat Loss Calculations

Heat loss is the number every other decision depends on, and it is the one most often produced by a rule of thumb. Watts per square metre gets you a plausible boiler size and an indefensible underfloor design, because it tells you nothing about the room with three external walls and a large glazed opening.

We calculate room by room to BS EN 12831 — fabric transmission through each element with its own U-value, thermal bridging, ventilation and infiltration on the appropriate basis, and intermittent-heating reheat allowance where the operating pattern justifies it. Every input is visible in the output, so your engineer or a building control officer can follow the arithmetic rather than take it on trust.

These calculations stand on their own for boiler and heat pump sizing, radiator scheduling, MCS documentation and compliance submissions — not only as an input to an underfloor design.

What you receive

Every item below is issued in your own template, with your layer conventions, title block and revision scheme.

  • Room-by-room heat loss schedule in watts and W/m²
  • Element-by-element fabric breakdown with U-value source stated
  • Ventilation and infiltration losses with the assumed basis
  • Thermal bridging allowance and its derivation
  • Whole-building design heat load and diversified plant load
  • Emitter or floor output requirement per room
  • Sensitivity note on the assumptions that most affect the result
  • Calculation appendix suitable for submission or audit

Production detail

Key production parameters for Heat Loss Calculations
Typical turnaround24 hours per dwelling, 3–5 days commercial
StandardsBS EN 12831, BS EN ISO 6946, CIBSE Guide A, MCS requirements
Design conditionsCIBSE / national external design temperatures by location
Deliverable formatsXLSX with visible formulae, PDF appendix
U-value handlingCalculated from build-up or taken from your specification
RevisionsTwo rounds included

Software and formats

We work in your toolchain. If something you use is not listed, ask — the list below is only what we use most.

In-house BS EN 12831 calculation suiteHevacompMagiCADLinearExcel

Frequently asked

Either. If you give us the construction we calculate U-values to BS EN ISO 6946 and show the layer-by-layer working. If your architect or energy assessor has issued values, we use those and cite the source so the two documents agree.

They are produced on the BS EN 12831 basis MCS requires, room by room, with the assumptions documented. The submission itself is made by the MCS-certified installer, who remains responsible for it — we provide the calculation and the appendix that supports it.

We apply the standard's default internal temperatures by room type unless your specification says otherwise, and we list every temperature used on the schedule so nothing is hidden. Where a client has house rules — many do for corridors and utility spaces — those become the account default.

Yes, on stated assumptions derived from the construction era and any survey information available, with a sensitivity note showing how much the result moves if those assumptions are wrong. For retrofit work that sensitivity range is often the most useful part of the output.